JANUS-R261 / JANUS-R261DC
125kW | 261kWh
产品亮点
More Versatility
· Compatible with hybrid PCS for PV+ESS application
· Scalable from kWh to MWh
· Applicable for ESS, charging, microgrids and more scenarios
Easier Deployment
· Plug & play, pre-commissioned for shortening deployment time
· Intelligent O&M to reduce OPEX
· Compatible with local service for customization
Higher Efficiency
· Lower inverter losses and LCOE
· Simplified architecture reduces potential failure points
· Remote intelligent commissioning with one-click control
Safe & Reliable
· Certified to IEC 61000, IEC 62619, IEC 62477, GB/T 36276
· Fire protection from cell to system for active safety
· Real-time BMS monitors and diverse local safety strategies
单页下载 | 产品手册
产品参数
型号:JANUS-R261
- Nominal Capacity
- 261.24kWh
- Cell Type
- LFP3.2V/314Ah
- Configuration
- 1P260S
- Charge/discharge Rate
- 0.5P
- DC Voltage
- 832V
- Voltage Range
- 728V~936V
- System Side Dimension(W*D*H)
- 1007±5x1345±5x2250±5mm
- Weight
- ≈2380kg
- Protection (IP) Rating
- IP54
- Noise Level
- 75±5dB@1m
- Operating Temperature Range
- -20°C~55°C (>45°C derating)
- Operating Humidity Range
- 0~95% (No condensation)
- Maximum Operating Altitude
- ≤2000m
- Thermal Management Method
- Smart Liquid Cooling
- Fire Suppression System
- Smoke Detector, Temperature Detector, Pack-Level Fire Suppression, Cabin-Level Fire Protection, AEROSOL
- Communication Interface
- Ethernet, RS485, CAN
- Communication Protocol
- Modbus RTU, Modbus TCP, CAN 2.0B, IEC 61850
- Certificates
- GB/T 36276, GB/T 34120, GB/T 34133
型号:JANUS-R261DC
- Nominal Capacity
- 261.24kWh
- Cell Type
- LFP3.2V/314Ah
- Configuration
- 1P260S
- Charge/discharge Rate
- 0.5P
- DC Voltage
- 832V
- Voltage Range
- 754V~936V
- Dimension(W*D*H)
- 1066±5x1346±5x2400±5mm
- Weight
- 2215±50kg
- Protection (IP) Rating
- IP54
- Noise Level
- 75±5dB@1m
- Operating Temperature Range
- -20°C~55°C (>45°C derating)
- Operating Humidity Range
- 0~95% (No condensation)
- Maximum Operating Altitude
- ≤2000m
- Thermal Management Method
- Smart Liquid Cooling
- Fire Suppression System
- Smoke Detector, Temperature Detector, Pack-Level Fire Suppression, Cabin-Level Fire Protection, AEROSOL Communication Interface: Ethernet, RS485, CAN
- Communication Interface
- Ethernet, RS485, CAN
- Communication Protocol
- Modbus RTU, Modbus TCP, CAN 2.0B, IEC 61850
- Certificates
- IEC 62619, IEC 62477-1, IEC 61000, UN 38.3